ABOUT IBVA- DEVELOPMENT  - MEDIA  - PUBLIC  - EXPERIMENT  - USER   - ORDER
About
Interactive Brainwave Visual Analyzer

The human forehead is the most developed part of the brain, it's shows personality. Like dolphins and cats, it's also called  "melon brain" and/or Third Eye. For example, to produce Alpha frequency (8 - 12 Hz) is easy to generate from the rear part of the brain, not easy to generate from the forehead. IBVA's very high quality amplifier & visualization technique can show Left & Right forehead brain wave activity changes very clearly in real time;  it can also show Left & Right brain wave phase coherence for each frequency. Coherence does not depend on brain power. In case it shows coherence, then we can say that the Third Eye is open this time.

Left & Right brain usually work independently, so coherence will happen randomly. But for the person who trains well his or her Third Eye, they can show coherence more continuously. In that case, the Left and Right brain can make a more clear image in the mind and/or make a path way to the mind's hyper space time dimension.
Then mind & brain are connected to hyper space time dimension and/or to our world.

IBVA can visualize brain wave in real time 3 D mapping; it can  also control many media such as QuickTime Movie, Sampling Sound, MIDI sound, 3 D sound position, Sound Effect. It can send messages in real time to other machines as well, such as PC, Lighting System, Laser System, Animation System, 3 D computer, graphics System, MP 4 computer System, MAX System. We can use Left & Right and Coherence brain wave information for all of these purposes - new Biofeedback experience.

The IBVA system has three models. One channel system, Two channel system and Two channel & coherence system.
One channel system shows forehead brain wave activity.
Two channel system can show left & right hemisphere brainwave, or two people's forehead brain wave in same time.

Two channel & coherence system use special modification version of transmitter, need to use PCI serial card, in case Mac doesn't have two serial ports. Receiver out put is serial.  


EASY TO CONNECT

Putting on head band, sensor will catch brainwaves, data will be sent from special transmitter  wirelessly. The receiver needs to be connected to your computer by cable.                
   

                                                          

receiver gets charged by computer, connect to LED very quickly. :

 

   1 ch head band with one channel transmitter.



The transmitter has brain wave as sound output from mini jack. Two channel brain wave can record into stereo line input of camcorder, MD & other recording devices.
In you are using 4 truck sounds camcorder, you can record two channel brain waves and stereo sound.
You don't need to use computer for this recording operation.
Later, to play back two channel brain waves and video image on Mac, connect recording device's line output to receiver's tape input & recording device's firewire, then connect to Mac firewire connector. To see video image on Mac, you need to use video application.

           
PORTABLE COHERENCE & IMAGE RECORDING SYSTEM:

(to enlarge, click the pict.)



 
Record two channel brain wave & video image.  Then playback with Mac.
IBVA System PHOTO S:      IBVA System PHOTO L:


IBVA application has two modes. Mode one is  Quick draw mode for long time and static display, and other is OpenGL for more real-time display and feedback.
 

  -  - 

(to enlarge, click the pict.)

Added Open GL (most popular for 3D CG program interface),  to make FFT brainwave analysis results. This OpenGL FFT analysis can operate graph or light source in 3D by mouse operation. By this operation, you can not just see graph on the screen, you can see 3 D analysis graph  on upper front of the same screen. Dismissable brainwaves cause big signal, you can check from different position. OpenGLFFT analysis mode is prepared for 6 different type of displays to effect your eye sight.




(to enlarge, click the pict.)

This screen shot shows openGL FFT display on top.   Normal FFT display or Raw data display  on the back. It shows, right and left brainwave data in 2ch, coherence on the back, relative coherence in front. You can see these images from 3D angles, and you can control movie or sound.To  out put MIDI info, switch each frequency & amplitude.


(to enlarge, click the pict.)

Quck Draw mode. 2 ch FFT with peak display on the back, and raw data and holizontal bar on front.



The IBVA System  can be used for end users to developers. Our clients include some of the best research and development companies.
We are looking for developping interesting new system.



APPLICATIONS OF THE IBVA SYSTEM INCLUDE:
Develop psychic state and produce inner balancing.
Self mind control training.
Sleep state and hypnosis analysis.
Stress reduction and pain control.
Meditation training.
Image programming for sports training and problem solving.
New form hypermedia, multimedia, and virtual reality.
Control other machines by brain wave.
Increase creativity for musicians, artists, TV/movie directors and actors.
Tool for psychoanalysis and hospital/home care.
Super learning for language or any educational subject.
Advanced teaching systems.
Help for disabled people.
Environmental, scientific, architectural, corporate, and consumer research.
New tool for musicians, artists, MP 4 directors, digital event place & brain VJ.
Psychic research.
Crop Circle research.
Alien abduction research.


IBVA FEATURES:
Wireless transmitter allows you free movement up to 30 feet away, that is depend on environment's radio condition.
Ultra low noise balanced DC coupling amplifier. Max input 100 micro V p-p, minimum digital resolution is 100 micro V p-p / 256 = 0.390625 micro V p-p.
FFT point can be selected from 128 (0.9375 Hz), 256 (0.46875 Hz), 512 (0.234375 Hz resolution).
Transmitter has mini-out jack that can be connected to a portable audio or video recorder; no computer is needed for data acquisition.
Remote analysis data can be sent and analyzed in real-time over a network or modem connection.


Data can be fully exported in raw data, FFT & average formats.

Support for additional serial ports via plug-in boad; allows extensive serial input & output control.
Infinite real-time data acquisition (depend upon hard drive size).
Real-time 3-D & 2-D FFT with peak indicator, Raw Data, and Horizontal Bar displays with Quick Draw mode.
Full 24 bit color support; data can be analyzed with any standard or user customized color palettes; color cycling available in 8 bit mode with Quick Draw mode.

Interactive real-time FFT filtering with Quick Draw mode.
Real-time 3-D FFT (left, right, coherence and relative coherence), raw wave, sphere frequency and six brain wave switchs on one OpenGL display.
Full brainwave drive Quick Time Movie, Quick Time MIDI control; user configurable.
Full Brain wave driven sound control, support for 16 bit sound; user configurable.
Full image capture and playback control; user configurable.
Brain wave driven starsBrain & brainSkyfly, animation is included.
3D sound effect mixer driven by 3D image movement and brain wave.
Extra development kit can create more intensive interaction such as network connection, 3 D animation control and external MIDI device control.
With option cable & adapter, IBVA can see muscle movements (EMG) and heart rate (EKG). To see coherence with brain wave and EKG is one of very new interesting experience = body and mind harmony.


Hardware specifications:
 

IBVA TRANSMITTER:
Head band, brain wave sensor, amplifier, A/D converter and radio transmitter.

Power supply :
9V alkaline battery (8 hour continuous operation) or 9V standard or Ni-Cd or Nickel-Metal Hydride battery (2 hour continuous operation).
Dimension: W94 x H57 x D26 mm
Weight: 105g (including battery)
Switch: Power switch with LED indicator.
Connector: Brain wave data output mini-jack for external brain wave recording. Need to use recording device that has 10K to 100K ohm line input (about 0.1V to 1V p-p) & audio frequency range 500Hz to 13KHz, SN upto 40dB.
Head sensor input connector : 3P.
Operating radio frequency: 275MHz, 295MHz (Standard), 315MHZ (Blue Laval).


EEG amplifier specification :

Ultra low noise balanced DC coupling amplifier. Amplifier differential impedance is 10 T ohm, Input Bias current is ±1.2 PA .. ±2 PA.
Input  amplifier noise at 10 Hz:  Voltage noise :0.6 µ V rms .. 0.7 µV rms. Current noise: 12 fA p-p .. 15 fA p-p.
Input Noise that depend on source impedance at 10 Hz: 1 M ohm source impedance: 2.4 µ Vp-p. 100 K ohm source impedance: 1.2µ Vp-p.


Accessories:
Head sensor. Disposable electrodes.


IBVA RECEIVER:

radio receiver and convert to RS422 format.

Power supply: From computer or adapter.
Dimension: W82 x H31 x D126 mm
Weight: 135g

Switch: Input select switch for radio/sound and output select switch for ON/OFF.
Connector: Brain wave data input mini-jack for external brain wave playback. 100 K ohm line input (about 0.15 V to 1.5 V p-p. 0.023 to 0.23 V rms).
Serial Connector: RS-422 serial port connector (Mini-DIN 8 pin) input and output.
Operating radio frequency: 275MHz, 295MHz (Standard), 315MHZ (Blue Laval).
Accessories: One bar antenna and one RS422 cable. 


For one or two channel system:
IBVA receiver needs to used with USB serial adapter Keyspan "USA-28X".
 
 
USA-28X    


For two channel and coherence system:
need to use PCI serial card
MegaWolf "Romulus"/ "Remus"  4 / 2 port PCI Serial expansion card.
abd/or Keyspan SX PRO Serial card. (need to set Receive FIFO = OFF in advanced setup)
 
For USB port Mac, need to use two "USA-19HS". (need to set Receive FIFO = OFF in advanced setup)
and/or ATEN UC-RS232A connect to two USB port.


                                         

                             ATEN UC-RS232A  USA-19HS                   "Romulus/4"     "Remus/2"// Keyspan SX PRO Serial card.


More information for Hardware.
More information for coherence.

IBVA SYSTEM PACKAGE
UPGRADE KIT

Product specification are subject to change without notice.
IBVA is not medical proofed.