About
Interactive
Brainwave
Visual Analyzer
The
human forehead
is the most developed part of the brain, it's shows personality. Like
dolphins
and cats, it's also called "melon brain" and/or Third Eye. For
example, to produce Alpha frequency (8
- 12 Hz) is easy to generate from the rear part of the brain, not easy
to generate from the forehead. IBVA's very high quality
amplifier & visualization technique
can show Left & Right forehead brain wave activity changes very
clearly
in real time; it can also show Left & Right brain wave phase
coherence for each frequency. Coherence
does not depend on brain power. In case it shows coherence, then we can
say that the Third Eye is open this time.
Left
& Right brain usually work
independently,
so coherence will happen randomly. But for the person who trains well
his
or her Third Eye, they can show coherence
more continuously. In that case, the Left
and Right brain can make a more clear image in the mind and/or make a
path
way to the mind's hyper space time dimension.
Then mind & brain are connected to
hyper space time dimension and/or to our world.
IBVA
can visualize
brain wave in real time 3 D mapping; it can also control many
media
such as QuickTime Movie, Sampling Sound, MIDI sound, 3 D sound
position, Sound Effect. It can send
messages
in real time to other machines as well, such as PC, Lighting System,
Laser
System, Animation System, 3 D computer
graphics System, MP 4 computer System,
MAX System. We can use Left & Right and Coherence brain wave
information
for all of these purposes - new Biofeedback
experience.
EASY
TO CONNECT
Putting
on head band, sensor will
catch brainwave, data will
be sent from special transmitter by wireless. receiver need to be
connected
to your computer by cable.
receiver
get charged by computer, connection LED very
quickly. :

1 ch head band with
one channel
transmitter
The
transmitter has
brain wave as sound output from mini jack. Two channel brain wave can
record
into stereo line input of camcorder, MD & other recording device.
In case use 4 truck sound camcorder then
can record two channel brain wave and stereo sound.
No need to use computer for this recording
operation.
Later, for play back two channel brain
wave and video image in Mac is connect recording device's line output
to
receiver's Tape input & recording device's firewire connect to Mac
firewire connector. To see video image in Mac need to use video
application.
PORTABLE
COHERENCE
&
IMAGE
RECORDING
SYSTEM:
(to enlarge, click
the pict.)

Record
two channel
brain
wave & video image. Then
playback
with Mac.

Record
two channel brain wave,
stereo sound &
video
image. Then playback with Mac.
IBVA
System
PHOTO
S: IBVA
System
PHOTO L:
IBVA
application has
two mode. Mode one is Quick draw mode for long time and static
display,
and other is OpenGL for more real-time display and feedback.
- -
(to
enlarge, click the pict.)
Added
Open GL
(most popular for 3D CG program interface)
to make FFT brainwave analysis results. This OpenGL FFT analysis can
operate
graph or light source in 3D by mouse operation. For this, not just
seeing
graph by upper front, you can see 3 D analysis graph from main
different
positions. dismissable brainwaves cause of big signal, you can check
from
different position. OpenGLFFT analysis mode prepared 6 different type
of
display to effect eye sight.

(to enlarge, click the pict.)
OpenGL
FFT
display: Front. This screen
shot shows Normal FFT display or Raw data display are showed in the
back.
this display shows, right and left brainwave data in 2ch, coherence in
the back, relative coherence in front. You can see these images from 3D
angles can control movie or sound, out put MIDI info, by switching in
each
frequency & amplitude.

(to
enlarge, click the pict.)
Quck
Draw
mode. 2 ch FFT with peak display, Raw data and
hilizontal
bar.
The
IBVA System
can be use for end user to developers. Our clients
include some of the best research and development companies.
We are
looking
for developping interesting new system.
APPLICATIONS
OF THE IBVA SYSTEM INCLUDE:
Develop
psychic state and
produce inner
balancing.
Self mind control training.
Sleep state and hypnosis analysis.
Stress reduction and pain control.
Meditation training.
Image programming for sports training
and problem
solving.
New form of hypermedia, multimedia, and
virtual
reality.
Control other machines by brain wave.
Increase creativity for musicians,
artists,
TV/movie directors and actors.
Tool for psychoanalysis and
hospital/home care.
Super learning for language or any
educational
subject.
Advanced teaching systems.
Help for handy cap people.
Environmental, scientific,
architectural, corporate,
and consumer research.
New tool for musicians, artists, MP 4
directors,
digital event place & brain VJ.
Psychic research.
Crop
Circle research.
Alien abduction research.
IBVA
FEATURES:
Wireless
transmitter allows free
movement up
to 30 feet away, that depend on environment's radio condition.
Ultra low noise balanced DC coupling
amplifier.
Max input 100 micro V p-p, minimum digital resolution is 100 micro V
p-p
/ 256 = 0.390625 micro V p-p.
FFT point can select from 128 (0.9375
Hz),
256 (0.46875 Hz), 512 (0.234375 Hz resolution).
Transmitter has mini-out jack that can
be connected
to a portable audio or video recorder; no computer is needed for data
acquisition.
Remote analysis data can be sent and
analyzed
in real-time over a network or modem connection.
Data
can be fully exported in raw data, FFT & average formats.
Support for additional serial ports via
plug-in
boar; allows extensive serial input & output control.
Infinite real-time data acquisition
(dependent
upon hard drive size).
Real-time 3-D & 2-D FFT with peak
indicator,
Raw Data, and Horizontal Bar displays with Quick Draw mode.
Full 24 bit color support; data can be
analyzed
with any standard or user customized color palettes; color cycling
available
in 8 bit mode with Quick Draw mode.
Interactive real-time FFT filtering
with Quick
Draw mode.
Real-time 3-D FFT (left, right,
coherence and
relative coherence), Raw wave, sphere frequency and six brain wave
switch
in one OpenGL display.
Full Brainwave driven Quick Time Movie,
Quick
Time MIDI control; user configurable.
Full Brain wave driven sound control,
support
for 16 bit sound; user configurable.
Full image capture and playback
control; user
configurable.
Brain wave driven starsBrain
& brainSkyfly
animation is included.
3D sound effect mixer driven by
3D image
movement and brain wave.
Xtra development kit, can create more
intensive
interaction such as network connection, 3 D animation control and
external
MIDI device control.
With option cable & adapter, IBVA
can see
muscle movements (EMG) and heart rate (EKG). To see coherence with
brain
wave and EKG is one of very new interesting experience = body and mind
harmony.
- Recommended
MAC system:
-
- PowerMac,
PowerBook
which has serial port.
- PowerMac, PowerBook,
iMac,
iBook which
has
USB port. (need to use USB serial adapter)
- PowerMac (G3 & G4) w.
PCI
slot.
(need to
use PCI serial card)
- RAM 128 MB or more. Need
50 MB
or more
application
space. Hard disk space 100 MB or more. For install all IBVA DVD need 2
GB.
- For OpenGL operation,
minimum
500 M Hz
G3 or
G4 is good operation.
- (IBVA V2 doesn't work w.
68K
Mac. IBVA
V1.8.8c
is included for use with 68K Mac)
- SYSTEM:
-
- MAC
OS 8.6
to 9.2.3, OpenGL, Quick Time
V5.02
to 6.3
- In case you use
USB
serial
adapter,
then need
to install extension file for that adapter.
- In case you use
PCI
serial
card, then
need
to install extension file for that card.
- In case you use
Apple
MIDI
manager then
need
to install extension file for that.
- OSX 10.2.6 classic
mode
works
with IBVA
V2.5.7.1
but with no QT MIDI, 3D sound.
IBVA
TRANSMITTER:
Head
band, brain wave sensor, amplifier, A/D converter and radio transmitter.
Power
supply :
9V alkaline battery (8
hours
continuous operation) or 9V standard or Ni-Cd or Nickel-Metal Hydride
battery
(2 hour continuously operation).
Dimension: W94 x H57 x D26 mm
Weight: 105 g (include battery)
Switch: Power switch with LED
indicator.
Connector: Brain wave data output
mini-jack
for external brain wave recording. Need to use recording device that
has
10K to 100K ohm line input (about 0.1V to 1V p-p) & audio frequency
range 500 Hz to 13 KHz, SN upto 40dB.
Head sensor input connector : 3P.
Operating radio frequency: 275
MHz, 295
MHz
(Standard), 315 MHZ (Blue Laval).
EEG amplifier specification :
Ultra low
noise balanced DC coupling
amplifier.
Amplifier differential impedance is 10 T ohm, Input Bias current is
±1.2
PA .. ±2 PA.
Input amplifier noise at 10
Hz:
Voltage noise :0.6 µ V rms .. 0.7 µV rms. Current noise: 12
fA p-p .. 15 fA p-p.
Input Noise that depend on source
impedance
at 10 Hz: 1 M ohm source impedance: 2.4 µ Vp-p. 100 K ohm source
impedance: 1.2µ Vp-p.
Accessories:
Head
sensor. Disposable electrodes.
IBVA
RECEIVER:
radio
receiver
and convert to RS422 format.
More
information for Hardware.
More
information
for coherence.
IBVA
SYSTEM
PACKAGE
UPGRADE
KIT
Product
specification are
subject to
change without notice!
IBVA is not medical
proofed.